In this division, we cooperate with our sister company cericom.
c-mark consists of a module with laser and 2D-scanner and a lens, optionally available with variable focal lengths. A particular adapter plate enables simple and flexible integration of the lasermarking module into the existing system technology and facilitates maintenance and replacement. The rotatable laser scan head enables variable exit of the laser beam, so that processing can also be carried out can also be carried out simply “overhead”, for example.
It can be used wherever high quality markings are required or copyright is an issue for example, in the marking of safety glass, in the automotive industry, in medical technology or for jewelry and perfumes. c-mark enables easy integration into existing plants and machines and is also available as an alternative “stand-alone solution”.
Parameter | c-mark-economy | c-mark-economy | c-mark-economy | c-mark-economy |
Laser | ||||
Laser | CO2 (M2<1.2) | CO2 (M2<1.2) | CO2 (M2<1.2) | CO2 (M2<1.2) |
Max. laser power | 30 W | 30 W | 30 W | 30 W |
Power stability | ± 6% from cold, guaranteed | ± 6% from cold, guaranteed | ± 6% from cold, guaranteed | ± 6% from cold, guaranteed |
Cooling | Air of fan | Air of fan | Air of fan | Air of fan |
Optical system | ||||
Lens-Focal length (ZnSe) | F-75 | F-100 (standard) | F-150 | F-200 |
Marking area [mm x mm] | 50 x 50 | 70 x 70 | 105 x 105 | 140 x 140 |
Focus Diameter [μm] | ~ 170 | ~ 210 | ~ 290 | ~ 360 |
Resolution [dpi] | ~ 145 | ~ 115 | ~ 90 | ~ 70 |
Max. mark speed | > 1000 marking dots / sec | > 1000 marking dots / sec | > 1000 marking dots / sec | > 1000 marking dots / sec |
Control | ||||
Computer | Integrated Shuttle PC, Windows ® 10 | Integrated Shuttle PC, Windows ® 10 | Integrated Shuttle PC, Windows ® 10 | Integrated Shuttle PC, Windows ® 10 |
Interfaces | 2x USB, 2x Ethernet, 1x HDMI | 2x USB, 2x Ethernet, 1x HDMI | 2x USB, 2x Ethernet, 1x HDMI | 2x USB, 2x Ethernet, 1x HDMI |
Interfaces Laser Control | Laser-Interlock, Marking-Start (24 VDC), Marking-Stop (24 VDC), E-Stop, Error-Reset, Laser-Busy, optional digital I/O‘s (24 VDC) | Laser-Interlock, Marking-Start (24 VDC), Marking-Stop (24 VDC), E-Stop, Error-Reset, Laser-Busy, optional digital I/O‘s (24 VDC) | Laser-Interlock, Marking-Start (24 VDC), Marking-Stop (24 VDC), E-Stop, Error-Reset, Laser-Busy, optional digital I/O‘s (24 VDC) | Laser-Interlock, Marking-Start (24 VDC), Marking-Stop (24 VDC), E-Stop, Error-Reset, Laser-Busy, optional digital I/O‘s (24 VDC) |
Software | C-Control V3 (C-Mark Edition) | C-Control V3 (C-Mark Edition) | C-Control V3 (C-Mark Edition) | C-Control V3 (C-Mark Edition) |
Options / Accessoires | ||||
Mounting Angle of Scanner (min. Working distance) | 0° (77.8 mm); 90° (49.1 mm); 180° (56.1 mm); 270° (49.1 mm) | 0° (77.8 mm); 90° (49.1 mm); 180° (56.1 mm); 270° (49.1 mm) | 0° (77.8 mm); 90° (49.1 mm); 180° (56.1 mm); 270° (49.1 mm) | 0° (77.8 mm); 90° (49.1 mm); 180° (56.1 mm); 270° (49.1 mm) |
Additional optional accessoires | - Foot switch for efficient and user friendly control - Exhaust systems | - Foot switch for efficient and user friendly control - Exhaust systems | - Foot switch for efficient and user friendly control - Exhaust systems | - Foot switch for efficient and user friendly control - Exhaust systems |
Dimensions / Installation / Laser Safety | ||||
Dimensions marking module (L x H x W in mm) | 774 x 178,5 x 143 | 774 x 178,5 x 143 | 774 x 178,5 x 143 | 774 x 178,5 x 143 |
Weight of marking module (incl. laser and laser scanner) | 18kg | 18kg | 18kg | 18kg |
Cable length | 3 m (standard), up to 20 m draig chain compatible | 3 m (standard), up to 20 m draig chain compatible | 3 m (standard), up to 20 m draig chain compatible | 3 m (standard), up to 20 m draig chain compatible |
Ambient conditions | Operating temperature range +5 to +35° C Relative humidity max. 90 %; Non-Condensing | Operating temperature range +5 to +35° C Relative humidity max. 90 %; Non-Condensing | Operating temperature range +5 to +35° C Relative humidity max. 90 %; Non-Condensing | Operating temperature range +5 to +35° C Relative humidity max. 90 %; Non-Condensing |
Electrical Requirements | 115 - 230 VAC, 16 A, 50/60 Hz, 1/N/PE | 115 - 230 VAC, 16 A, 50/60 Hz, 1/N/PE | 115 - 230 VAC, 16 A, 50/60 Hz, 1/N/PE | 115 - 230 VAC, 16 A, 50/60 Hz, 1/N/PE |
Power Consumption | < 1000 W (incl. Cooler and Exhaust system) | < 1000 W (incl. Cooler and Exhaust system) | < 1000 W (incl. Cooler and Exhaust system) | < 1000 W (incl. Cooler and Exhaust system) |
System Protection | Marking Head: sealed against spray water (IP 54) Laser Rack Unit: dust protected (IP 20) | Marking Head: sealed against spray water (IP 54) Laser Rack Unit: dust protected (IP 20) | Marking Head: sealed against spray water (IP 54) Laser Rack Unit: dust protected (IP 20) | Marking Head: sealed against spray water (IP 54) Laser Rack Unit: dust protected (IP 20) |
Laser Class | CDRH Laser Safety, Laser Class 1-4 (depends on integration situation), CE certified | CDRH Laser Safety, Laser Class 1-4 (depends on integration situation), CE certified | CDRH Laser Safety, Laser Class 1-4 (depends on integration situation), CE certified | CDRH Laser Safety, Laser Class 1-4 (depends on integration situation), CE certified |